debug ulpp error

no debug ulpp error

Show the error information of ULPP, the no

operation disables the showing.

debug ulpp event

no debug ulpp event

Show the event information of ULPP, the

no operation disables the showing.

56.3 ULPP Typical Examples

56.3.1 ULPP Typical Example1

SwitchD

SwitchB E1/1

E1/2 SwitchC

E1/1

E1/2

SwitchA

Figure 56-3: ULPP typical example1

The above topology is the typical application environment of ULPP protocol.

SwitchA has two uplinks, they are SwitchB and SwitchC. When any protocols are not enabled, this topology

forms a ring. For avoiding the loopback, SwitchA can configure ULPP protocol, the master port and the slave

port of ULPP group. When both master port and slave port are up, the slave port will be set as standby state

and will not forward the data packets. When the master port is down, the slave port will be set as forwarding

state and switch to the uplink. SwitchB and SwitchC can enable the command that receives the flush packets,

it is used to associate with ULPP protocol running of SwitchA to switch the uplink immediately and reduce the

switch delay.

When configuring ULPP protocol of SwitchA, first, create a ULPP group and configure the protection VLAN of

this group as vlan10, then configure interface Ethernet 1/1 as the master port, interface Ethernet 1/2 as the

slave port, the control VLAN as 10. SwitchB and SwitchC configure the flush packets that receive ULPP.

SwitchA configuration task list: