Chapter 69 dying gasp configuration, 1 introduction to dying gasp, 2 dying gasp typical examples – PLANET WGSW-52040 User Manual

Page 504: 3 dying gasp troubleshooting, Chapter 69 dying gasp configuration -75, Ntroduction to, Ying, Ypical, Xamples, Roubleshooting

Advertising
background image

69-75

Chapter 69 Dying Gasp Configuration

69.1 Introduction to Dying Gasp

Dying gasp is power failure alarm function. It means that at the case of power failure, the switch can also send

information through the ethernet ports to notice the other switch that it is power failure.

Dying gasp is enabled as default, but it could run normally with the snmp management function. So the layer 3

interface should be configured on switch and make it connect to snmp management server. snmp trap should

be configured orderly.

69.2 Dying Gasp Typical Examples

The dying gasp function of the switch is enabled as default, but it could run normally with the snmp

management function.

Below are the configuration steps:

Switch(config)#snmp-server enable

Switch(config)#snmp-server securityip X.X.X.X

Switch(config)#snmp-server host X.X.X.X v2c switch

Switch(config)#snmp-server enable traps

Switch(config)#interface vlan N

Switch(config-if-vlanN)ip address Y.Y.Y.Y 255.255.255.0

69.3 Dying Gasp Troubleshooting

If there is something wrong when configuring dying gasp function, please check out if it is because of the

following reasons:

Make sure the layer 3 interface has been configured and connected to snmp server.

Make sure the address of snmp server. More than one snmp server address can be configured on

switch, but dying gasp trap packets will be sent to the last configured server when it is power failure.