ProSoft Technology MVI56-AFC User Manual

Page 109

Advertising
background image

MVI56-AFC ♦ ControlLogix Platform

Archives

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 109 of 316

February 25, 2011

bit 2 Diff. pressure input out of range -

bit 3 Flowing density input out of range -

bit 4 Water content input out of range -

bit 5 Diff. pressure low -

bit 8 Orifice characterization error -

bit 9 Analysis total zero -

bit 10 Analysis total not normalized -

bit 11 AGA8 calculation error -

bit 12 API calculation error, density correctio -

bit 13 API calculation error, Ctl -

bit 14 API calculation error, vapor pressure -

bit 15 API calculation error, Cpl -


Status Bits

bit 11 Meter was enabled -

bit 12 Backplane communication fault -

bit 13 Measurement configuration changed -

bit 14 Power up -

bit 15 Cold start -




AFC-56(16) Daily Archive Date: 16-09-2002 16:26:41
Site Name: MVI Flow Station
Project: AFC
___________________________________________________________________________

Meter 1:

Tag M01

Archive 1


Closing timestamp of archive 2002-04-27.00:00:02

Opening timestamp of archive 2002-04-26.23:59:42

Status bitmap (details below) 00h

Alarms bitmap (details below) 0000h

Flowing period 20

Event counter 53

Net accumulator (x f3) 234

Net accumulator residue (x f3) 0,1092186

Net flow rate (x f3/h) 40248,01

Temperature (°F) 15

Pressure (psig) 1000

Differential pressure (hw) 22

Relative density (60°F/60°F) 0,7404

Reference compressibility 0,9989

Flowing compressibility 0,9051

Fpv 1,0505

Velocity of approach factor Ev 1,0328

Expansion factor Y 0,9997

Discharge coefficient 0,6043


Alarm Bits

bit 0 Temperature input out of range -

bit 1 Pressure input out of range -

bit 2 Diff. pressure input out of range -

bit 3 Flowing density input out of range -

Advertising
This manual is related to the following products: