14.1.4 Configurable Options

Configurable options include:
 Gas analysis concentrations for up to 21 components
 Accumulator Rollover
 Reference temperature and pressure for both gases and liquids
 Orifice and pipe diameters, selection of type of taps, and tap locations, and

so on.

 Meter K Factor and Meter Factors with 5-point linearization curve
 Temperature, Pressure, and Density Correction for liquids
 Local Atmospheric (barometric) pressure
 Default process and operating parameters such as DP Threshold for flow

cutoff, and so on.

 Metric or US units
 User-selectable units for totalizers and flow rates on a per channel basis
 Resettable and non-resettable totalizers for every meter channel.

14.1.5 Supported Meters

The following meter types have been used with the MVI56-AFC module.

Because of the broad range of meters available in today’s market, refer to the

meter’s specifications and the contents of this manual to evaluate the use of the

AFC modules (even if the meter is listed here). If you have questions, please

contact ProSoft Technology Technical Support Group.

Meter Type

Configured As (Differential or Linear)

Turbine

Linear

Orifice

Differential

V-Cone

Differential. You must configure the meter as V-Cone type in the AFC Manager

(Meter Configuration / Calculation Options)

Wedge

Differential. Refer to Wedge Meter Applications (page 279) for information

about using the wedge meters.

Vortex

Linear or Differential

Ultrasonic

Linear or Differential

Coriolis

Linear or Differential

Note: For Vortex, Ultrasonic or Coriolis meters, the selection depends on the output generated by
the meter.
If the meter provides a pulse train representing the volume increment, the AFC meter should be
configured as Linear with Primary Input selected as Pulse Count.
If the meter provides the instantaneous flow rate, then the AFC meter should be configured as
Differential with Primary Input selected as Flow Rate.
Note: The module does not support applications to measure water, because the implemented
standards are applicable to hydrocarbon fluids only.