Archive Locations

Click the Modbus Addresses button on the Archive Configuration dialog box to

learn how to fetch an archive record of a specific age (procedure and Modbus

location), and even the actual Modbus address of a specific file archived datum

point (if you have highlighted the item in the archive record template).
The following table shows the current archive (Archive 0) location in the Primary

Modbus Slave for each of the first 8 meters. These addresses refer to the holding

register bank.

Archive 0 - Current Archives

Meter Start Daily Archive

End Daily Archive

Start Hourly Archive

End Hourly Archive

1

9900

9939

9950

9989

2

11900

11939

11950

11989

3

13900

13939

13950

13989

4

15900

15939

15950

15989

5

17900

17939

17950

17989

6

19900

19939

19950

19989

7

21900

21939

21950

21989

8

23900

23939

23950

23989


Refer to the Modbus Dictionary dialog box for the current archive addressing.
The following table shows the past archives location in the Primary Modbus

Slave for each of the first 8 meters. These addresses refer to the input register

bank.

Archives 1 to n - Past Archives

Meter Start Daily Archive

End Daily Archive

Start Hourly Archive

End Hourly Archive

1

0

1059

1060

2499

2

2500

3559

3560

4999

3

5000

6059

6060

7499

4

7500

8559

8560

9999

5

10000

11059

11060

12499

6

12500

13559

13560

14999

7

15000

16059

16060

17499

8

17500

18559

18560

19999