ProSoft Technology MVI56-AFC User Manual

Page 168

Advertising
background image

MVI56-AFC Backplane Communication

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 168 of 316

ProSoft Technology, Inc.

February 25, 2011

11.2.1 Function Block Structure

The first word of each output and input function block, called the "block ID",

specifies the block type, control flags, addressing, and additional information

depending on type. For each function block type, the matching input function

block (returned by the AFC) also contains a block ID. Portions of this word echo

the output verbatim, while the remainder may contain status information about

the result of the action.
Each output function block ID is verified by the AFC to be unambiguous; any

value that is out of range, or any undefined bit that is set to 1, causes a format

alarm.
The typical structure of a function block is shown in the following diagram:

Typical Output Function Block (OFB)

Element

Attribute

0

Block ID: Function Code, Processing Controls, Length or Meter/Stream
Selection

1

Data Block Length

2
. . .


. . .
N

Typical Input Function Block (IFB)

Element

Attribute

0

Block ID: Function Code Echo, Status and Alarms, Meter and Active Stream Numbers

1

Data Block Length

2
. . .


. . .
N

Advertising