ProSoft Technology MVI56-AFC User Manual

Page 171

Advertising
background image

MVI56-AFC ♦ ControlLogix Platform

MVI56-AFC Backplane Communication

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 171 of 316

February 25, 2011

11.2.2 Function Block Definition - 0: Null

Output Function Block ID

Function Block Name:

Null

Function Block ID:

0 decimal, 000000 binary, 0 dec.

Target:

Global

Data Block Length:

User Defined

Total Block Length:

(User Defined + 1) Elements

Description
This function block is used as a space filler only. It implies no action by the AFC.

Null: Output Function Block (OFB)

Null: Input Function Block (IFB)

Element

Attribute

Element

Attribute

0

Block ID - Function Code & Length

0

Block ID - Function Code

1

Null Data

1

2

2

n

n

Note: A Block ID with all 16 bits set to 0 is interpreted as a Null FB of length 1 (the Block ID itself).
Note also that because the Null FB implies no action, the settings of the "out" and "inp" bits are
irrelevant.
Note: Refer to Function Block Structure (page 168) for information on Bit 8 and 9 settings.

Advertising