MVI56-AFC Sample Logic

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 247 of 316

February 25, 2011

Example 2 - Read Net Accumulator Totalizer From Yesterday’s Archive (Meters
1 to 4) (assume orifice meters, gas product)
Perform the following steps:
This application only transfers 8 words (each totalizer occupies 2 words).

Because the number of words is less than 200, it means that only one Modbus

Gateway block will be used (AFC56.Modbus.Gateway[0])
1 Configure the AFC56.Modbus.BlockCount tag with a value of 1.
2 In order to identify the register addresses in the Primary Modbus Slave, refer

to the following spreadsheet that shows the addresses for the hourly and

daily archives:

Input Registers

Mete
r

Start Daily Archive

End Daily Archive

Start Hourly Archive End Hourly Archive

1

0

1059

1060

2499

2

2500

3559

3560

4999

3

5000

6059

6060

7499

4

7500

8559

8560

9999

5

10000

11059

11060

12499

6

12500

13559

13560

14999

7

15000

16059

16060

17499

8

17500

18559

18560

19999

9

20000

21059

21060

22499

10

22500

23559

23560

24999

11

25000

26059

26060

27499

12

27500

28559

28560

29999

13

30000

31059

31060

32499

14

32500

33559

33560

34999

15

35000

36059

36060

37499

16

37500

38559

38560

39999

Each archive occupies a 30-word block. For example, for meter 1:

Archive

Start Register

End Register

Yesterday

0

29

2 days ago

30

59

3 days ago

60

89

4 days ago

90

119

5 days ago

120

149