The logic will continuously analyze each meter enable status. After the logic

determines that a specific meter is disabled (AFC56.DisableStatus.Meterx = 1)

the command bit (AFC56.DisableMeter.Meterx) will be unlatched.

Note: DO NOT create a rung in logic to constantly disable the meter. The command bit should be
toggled only once in order to disable the meter.

12.3.3 Enable Meter

Each meter can be enabled through logic. Refer to the AFC56.EnableMeter data

structure. Toggle each AFC56.EnableMeter.Meterx controller tag in order to

command the meter to be enabled.
The logic will continuously analyze each meter enable status. After the logic

determines that a specific meter is enabled (AFC56.EnableStatus.Meterx = 1) the

command bit (AFC56.EnableMeter.Meterx) will be unlatched.

Note: DO NOT create a rung in logic to constantly enable the meter. The command bit should be
toggled only once in order to enable the meter.