MVI56-AFC ♦ ControlLogix Platform

Diagnostics and Troubleshooting

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 261 of 316

February 25, 2011

Alarm Message

Description

Solution

Reference density

error

The density correction calculation
resulted in an error according to the

standard.

Alarm Code values::
0 = No alarm
1 = Low density (NGLs), input

outside API range
2 = High density (crudes & refined),

input outside API range
3 = Non-convergence
4 = Zero VCF
5 = Temperature above critical point
6 = Input density outside reference

fluid adjusted range
7 = Corrected density out of range
8 = Standard density input outside

API range
9 = Alpha input outside API range
Also check the input values and
calculation parameters for your

project.

Temperature

Correction error

The temperature correction
calculation OR the water temperature

correction calculation resulted in an

error according to the standard.

Alarm Code values:
0 = No alarm
1 = Low density (NGLs), input

outside API range
2 = High density (crudes & refined),

input outside API range
5 = Temperature above critical point
9 = Alpha input outside API range
Also see the Alarm Code for Water

Temperature Correction error.

Vapor pressure error The vapor pressure calculation

resulted in an error according to the

standard.

Alarm Code values:
0 = No alarm
1 = Expected vapor pressure above

range of TP-15 (stream's "Default

Vapor Pressure" is substituted)
2 = Vapor pressure > measured

static absolute pressure (vapor

pressure assumed to equal static

pressure)
3 = Both 1 and 2

Water Temperature
error (Alarm Code

only)

The water temperature correction
calculation resulted in an error
according to the standard. This Alarm

Code sets the "Temperature

Correction error" alarm bit.

Alarm Code values:
0 = No alarm
1 = Temperature < 0°C (32°F) or

> 138°C (280°F)