ProSoft Technology MVI56-AFC User Manual

Page 44

Advertising
background image

Meter Proving

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 44 of 316

ProSoft Technology, Inc.

February 25, 2011

Bidirectional Pipe Prover
This is similar to a unidirectional prover, except that use is made of the deadhead

transfer of the ball back to its starting point. Instead of returning the ball via a

separate path, valves are swung to reverse the direction of flow in the prover and

the ball is returned along its original path to trip the switches a second time in the

opposite order. The first pass of the ball is called the forward leg and the second

is called the backward or return leg. The pulse count for the run is then the sum

of the counts for the two legs. Because the run's pulse count arises from two

passes between the switches, a bidirectional prover need be only half the volume

of its unidirectional counterpart and can be correspondingly smaller.