background image

MVI56-AFC ♦ ControlLogix Platform

Accumulators

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 87 of 316

February 25, 2011

Reset from Ladder Logic
The ladder logic may send a meter signals block to command one or more

resettable accumulators to be reset. This feature is especially important for

applications involving field installations that require shipping and/or receiving

product batches of predetermined size. Refer to the Ladder Logic section for your

module type for more information.

Reset Upon Archive Period End or Reset Upon Event
Use AFC Manager to configure the resettable accumulator to be reset when the

archive period ends or when an event occurs. Refer to Event Log in the AFC
Manager User Guide
for more information on configuring and monitoring events.

Refer to Archives (page 91) for more information.

Reset When the Accumulator Rollover Value is Reached
The resettable accumulator is reset when the accumulator rollover value is

reached. You must configure the accumulator rollover value using the AFC

Manager software (Meter Configuration). Refer to the AFC Manager User Manual

for more information about this subject.
For multiple-stream firmware (version 2.05 or later), resetting a resettable

accumulator resets that accumulator for both the meter and for all its streams.