Meter Proving

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 60 of 316

ProSoft Technology, Inc.

February 25, 2011

Prover Position: Ready for Return
For bidirectional provers only, the prover's ball or piston is ready for launching

into the stream for the return leg.

Prover Position: Valve Sealed Behind Ball
The prover's ball or piston has been launched into the stream and the sealing

valve has been closed behind it. For a bidirectional prover, this is the start of the

forward leg.

Prover Position: Valve Sealed Behind Ball, Return Leg
For bidirectional provers only, the prover's ball or piston has been launched into

the stream for the return leg and the sealing valve has been closed behind it.

Prover Temperature
Absolute
This value is the process input temperature of the prover (traditional or master

meter) in units relative to absolute zero, and is required for some calculations.

This value is meaningful only while a prove is active.
Conventional
This value is the process input temperature of the prover (traditional or master

meter) in conventional units. For a traditional prover with dual transmitters, this is

the average of the two inputs. This value is meaningful only while a prove is

active.

Prover Pressure
Absolute
This value is the process input pressure of the prover (traditional or master

meter) in absolute units. This value is calculated as (gauge pressure ) +

(barometric pressure). This value is meaningful only while a prove is active.
Gauge
This value is the process input pressure of the prover (traditional or master

meter) in gauge units. For a traditional prover with dual transmitters, this is the

average of the two inputs. This value is meaningful only while a prove is active.