8 pulse frequency integration with gas product, 9 flow rate integration with liquid product – ProSoft Technology MVI56-AFC User Manual

Page 291

Advertising
background image

MVI56-AFC ♦ ControlLogix Platform

Reference

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 291 of 316

February 25, 2011

14.5.8 Pulse Frequency Integration with Gas Product

Start Offset

End Offset

Data Format

Type

Description

10

11

Accumulator

Snapshot

Accumulator totalizer, net

12

13

Floating point

Snapshot

Accumulator residue, net

14

15

Floating point

Flow weighted
average

Flow rate, net

16

17

Floating point

Flow weighted
average

Temperature

18

19

Floating point

Flow weighted
average

Pressure

20

21

Floating point

Flow weighted
average

K-Factor

22

23

Floating point

Flow weighted
average

Meter Factor

24

Word

Flow weighted
average

Relative density e-4

25

Word

Flow weighted
average

Compressibility, reference, e-4

26

Word

Flow weighted
average

Compressibility, flowing, e-4

27

Word

Flow weighted
average

Supercompressibility, e-4

28

29

Floating point

Flow weighted
average

Pulse Frequency

14.5.9 Flow Rate Integration with Liquid Product

Start Offset

End Offset

Data Format

Type

Description

10

11

Accumulator

Snapshot

Accumulator totalizer, net

12

13

Floating point

Snapshot

Accumulator residue, net

14

15

Floating point

Flow weighted average Flow rate, net

16

17

Floating point

Flow weighted average Temperature

18

19

Floating point

Flow weighted average Pressure

20

21

Floating point

Flow weighted average Flow Rate Input

22

23

Floating point

Flow weighted average Density Input

24

Word

Flow weighted average Corrected density (scaled integer)

25

Word

Flow weighted average CTL e-4

26

Word

Flow weighted average CPL e-4

27

Word

(available)

28

Word

(available)

29

Word

(available)