background image

Accumulators

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 84 of 316

ProSoft Technology, Inc.

February 25, 2011

7.1

Accumulator Totalizer and Residue

The accumulators are expressed as the totalizer and residue parts. This

implementation allows the accumulation of a wide range of increments, while

keeping a high precision of fractional part with an approximately constant and

small round off error.
The totalizer stores the integral part of an accumulator as a 32-bit (or split)

integer. The residue is the fractional part (always less than 1.0) expressed as a

32-bit IEEE floating point.
The Total Accumulator is given by the formula:

ACCUMULATOR = TOTALIZER + RESIDUE

Example
If the meter monitor window shows the following values for the accumulators:

The total resettable accumulator 1 value (net) is 12.8031153.
The accumulator totalizer values can be configured to "split" with the low-order

word rolling over from 9999 to 0000 at which time the high-order word is

incremented. Refer to the AFC Manager (AFC Manager / Meter Configuration /

Split Double Accumulators) to select this feature.
A 32-bit value is more suited to computation and has a greater range than a split

value, whereas a split value is easier to read when it is represented as a pair of

16-bit numbers, as in a processor data file.