ProSoft Technology MVI56-AFC User Manual

Page 59

Advertising
background image

MVI56-AFC ♦ ControlLogix Platform

Meter Proving

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 59 of 316

February 25, 2011

Prover Phase
These bits report the state of the run as known by the proving hardware. These

values are chosen specifically for compatibility with several kinds of proving

hardware, so that the work necessary for the PLC to translate hardware register

values into these values required by the AFC is minimized and in many cases

can be reduced to a simple mask-and-copy. There are 8 values ranging from 0-

7. These values are:

Value Name

Description

0

Prover not selected (not ready)

This is the normal value when no proving run is in

progress.

1

Prover active, not yet counting

The counter card has been initialized for a proving
run, but the ball or piston has not yet passed the
first switch. Counting of the pulses for the run has

not yet begun.

2

Prover active, past first switch and

counting

The ball or piston has passed the first switch but not
yet passed the second switch, and the run counter

is counting pulses. For bidirectional provers, this is

the forward leg.

3

Prover active, past second switch

This state is for bidirectional provers only. The ball

or piston has passed the second switch of the
forward leg, the run counter has been stopped, and

the intermediate count for the forward leg is

available. During this state
the proving hardware should be swinging valves to

reverse the stream's direction of flow through the

prover, preparing it for the return leg.

4

Prover active, past first switch return

leg

This state is for bidirectional provers only. The ball
or piston has passed the first switch on the return

leg but not yet passed the second switch, and the

run counter is counting pulses.

5

Run Complete

The ball or piston has passed the second switch
(for bidirectional provers, the second switch of the

return leg), the run counter has been stopped, and
the count for the run is available. For a bidirectional

prover, this count may be either the count for only

the return leg or the count for the entire run; use

prover option "Return leg pulse count is round-trip

count" (register 65011 bit 4) to specify which.

6

Prover not selected (not ready)

Some kinds of proving hardware report this value
for a counting mode unrelated to proving. The AFC

treats this value the same as value 0.

7

Prover not selected (not ready)

Some kinds of proving hardware report this value
for a counting mode unrelated to proving. The AFC

treats this value the same as value 0.

Prover Position: Ready for Launch
The prover's ball or piston is ready for launching into the stream. For a

bidirectional prover, this is the launch of the forward leg.