February 25, 2011

Prove-enable Error Code
This code reports the result of the most recent attempt to enable a prove. If the

code is zero, the prove was successfully enabled; a non-zero code reports the

reason for failure. The values are:

Value

Name

Description

0

The new prove has been

enabled

The new prove has been enabled

21

Requested meter number

The Requested meter number (register 65300) is out
of range, or, for a master meter prover, is the same

as that of the master meter (an attempt to self-prove

the master meter)

22

Line meter not liquid pulse

At the present time, the meter to be proved may only

be a liquid pulse meter.

23

Incompatible measurement

standard

At the present time, the configuration of both the
prover and the line meter to be proved must specify

the same system of measurement units (US, SI) and

the same liquid density units selection (kg/m3, Rd/60,

°API).

24

Unimplemented product group

Because of the nature of the proving calculations at
the present time, not all product groups are provable.
Meters configured for these product groups are

provable:


Liquid (crude oils and JP4)



Liquid (refined products: gasolines, jet fuels, fuel

oils, except JP4)



Liquid (NGLs and LPGs)



Liquid (lubricating oils)



Liquid (special applications)

Meters configured for these product groups are not

provable:


Gas



Liquid (oil-water emulsion of crudes)



Liquid (oil-water emulsion of NGLs)

25

Unimplemented measured

quantity

At the present time, only pulse meters whose pulse

train represents gross volume can be proved.

28

Line meter in calibration

The meter to be proved has at least one process
input in calibration mode. Ensure that all process

inputs are live before attempting to prove the meter.

29

Line meter not enabled

The meter to be proved is not enabled.

32

Master meter not liquid pulse

At the present time, a master meter prover must be a

liquid pulse meter.