MVI56-AFC ♦ ControlLogix Platform

Meter Proving

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 43 of 316

February 25, 2011

Unidirectional Pipe Prover

This is a long pipe, with a ball or piston that fills the pipe and moves with the

fluid flow. At each end of the pipe is a switch that is tripped when the ball

passes it. A proving run counts the pulses occurring between the switch trips.

A run is prepared by positioning the ball in a cul-de-sac upstream of the first

switch, ready to be injected into the stream. At the end of the run, the ball is

extracted from the stream and returned via another path to the upstream end.

In order to calculate a meter factor with sufficient precision, the prover volume

must be large enough to count sufficient pulses. Therefore, unidirectional

provers can be quite large.