11.2.10 Function Block Definition - 14: Meter Archive Fetch

Note: This function is available only in versions 2.04 and later.

Output Function Block ID

Input Function Block ID

Function Block Name:

Meter Process Variables

Function Block ID:

14 decimal, 001110 binary, 14336 dec.

Target:

Selected Meter Number

Data Block Length:

41 Element

Total Block Length:

42 Elements