Meter Channel Functionality

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 32 of 316

ProSoft Technology, Inc.

February 25, 2011

3.1

Meter Channels

Each meter channel can be assigned as a linear meter (e.g. a pulse meter) input

or as a differential meter (e.g an orifice meter) input for flow measurement using

either SI (metric) or US units. Selecting the differential meter causes the module

to use the AGA 3 standard for flow calculation (for a gas orifice meter you may

optionally choose ISO 5167-2 instead). Selecting the linear meter causes the

module to use the AGA 7 standard for gas flow calculation.
Each meter channel can be configured for gas or liquid (crude or refined)

product. The Product Group essentially selects the API/AGA Standards to be

used in calculating flow rates/increments.
Selecting "Gas" causes use of AGA8 and either AGA3 or AGA7 Standards.
Selecting any liquid group causes use of API MPMS Chapter 11(tables

23/24/53/54) and related Standards. "Crude oils, JP4" and "Oil-water emulsion

Crd)" use the, "A", tables. “NGLs, LPG’s” and “Oil-water emulsion (NGL) use the

“E” tables. "Refined Products" use the "B" tables. "Lubricating oils" use the "D"

tables, and "Special applications" use the "C" tables. "Crude oils, JP4" and

"NGLs/LPG" are used for propane, butane, NGLs (natural gas liquids), and crude

oils which are relatively water-free (less than 5 percent). The two "Oil-water

emulsion" groups are used for crude and NGL/LPG that might have a high

concentration of water for which API MPMS Chapter 20.1 is applicable. "Refined

products (xJP4)” is used for lighter refined liquids such as gasolines, jet fuels

(except JP4), and fuel oils. "Lubricating oils” is used for heavier refined liquids.

"Special applications" is used for those liquids that cannot reasonably be

assigned to one of the other groups; for this product group an explicit coefficient

of thermal expansion must be supplied.
The following table provides a brief overview of the standards used according to

the Meter Type and Product Group:

Meter Type

Product Group

Standards

Differential

Gas

AGA8, AGA3/ISO5167

Differential

Liquid

MPMS ch 11 AGA3/ISO5167

Linear

Gas

AGA8, AGA7

Linear

Liquid

MPMS ch 11, MPMS ch12.2

Note: The meter channel must be disabled in order to change its meter type and product group.