MVI56-AFC Backplane Communication

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 176 of 316

ProSoft Technology, Inc.

February 25, 2011

Input Function Block ID

Function Block Name:

Meter Process Variables

Function Block ID:

8 decimal, 001000 binary, 8192 dec.

Target:

Selected Meter Number

Data Block Length:

11 Elements

Total Block Length:

12 Elements

Description
This block provides fresh values of the process inputs to and returns results from

the latest meter calculation scan. The meter is scanned continuously; therefore

several calculations may occur between applications of this block. Process inputs

in the output block are meaningful depending on configuration. For example, the

fourth input is seen as differential pressure, pulse count, flow rate, or ignored

depending on the meter type; the water content is meaningful only for liquids.
The input block always returns an alarm indicator as part of the block ID; the

remaining 11 words are freely selectable from the entire meter database, with the

default selection including detailed alarms, net volume accumulator, net volume

flow rate, correction factors, and intermediate values depending on configuration.
The Meter Process Variable Block must be set up for one of the following meter

types:
 Orifice (Differential) Meter with Gas Product
 Pulse (Linear) Meter with Gas Product
 Orifice (Differential) Meter with Liquid Product
 Pulse (Linear) Meter with Liquid Product
 Flow Rate Integration with Gas Product
 Pulse Frequency Integration with Gas Product
 Flow Rate Integration with Liquid Product
 Pulse Frequency Integration with Liquid Product