14.1 General Specifications

 Process I/O: analog inputs (pressure, temperature, differential pressure

density) from analog modules and pulse inputs from pulse/frequency input

modules in rack

 Number of meter channels: 16 meters: differential (AGA3 or ISO5167) or

linear (AGA7) Gas; (MPMS Ch 12.2) Liquid.

Calculation Methods

 AGA3 (1992)
 AGA7
 AGA8 (1992) Detail Characterization Method
 API MPMS Ch 21.1, 21.2
 API Tables (API MPMS Ch 11.1) 23/53 and 24/54 for Hydrocarbon Liquids
 GPA TP-27 for Hydrocarbon Liquids (Tables 23E/24E)
 API MPMS Ch 11.2
 GPA TP-15 for Vapor Pressure Correlation
 Energy (heating value) for gases according to AGA 8 Appendix C-4
 API MPMS Ch 20.1
 ISO 5167
Supports energy measurement for gas applications
Meter I/O Scan Time: Less than one second for all channels.
Product Measurement: Hydrocarbon gases and liquids including refined

products
Process I/O Calibration Mode: Allows the calibration of transmitters without
interfering with the process update for the module or impacting measurement.
Data Archiving

 Hourly for 2 days for each meter run (48 records per channel)
 Daily for 35 days

Note: The number of archives depends on the archive size you have configured. The default
values for a 30 word archive are 48 hourly archives and 35 daily archives.

 Extended Archive feature supports up to 1440 daily archives and 1440 hourly

archives stored on Compact Flash

 Each record consists of nearly 20 process and other variables. All archived

data is available in the onboard Modbus memory map.

 User may configure when archives are generated
 User may configure archive content (from pre-defined list)
 Archives can be exported to an Excel spreadsheet or printed to a local

printer.

Other Features

 Event Log with 1999-event buffer and timestamp.
 Virtual Slave with 20,000 re-mappable Modbus registers for contiguous

SCADA polling.

 Password protection