ProSoft Technology MVI56-AFC User Manual

Page 38

Advertising
background image

Meter Channel Functionality

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 38 of 316

ProSoft Technology, Inc.

February 25, 2011

3.6.5 Data Archiving

The module supports the archiving of data for each meter channel. Each time,

one record consisting of all the associated data is date and time stamped and

archived. This option allows for archiving each hour for 2 days (48 records per

meter run) and every day for 35 days (35 daily records per meter run) for each

meter channel. Each record consists of up to 40 process and other variables.

Archives are mapped to the local Modbus Table. Refer to Archives (page 91) for

more information about this topic.

3.6.6 Event Log Function

The module can log up to 1999 critical events in an Event Log File stored as a

set of easily accessible Modbus registers in non-volatile RAM. Changing critical

parameters, such as orifice plate size, Meter Base K factors, and Meter

Correction Factors, are time stamped and logged. Refer to Events for more

information about this topic.

3.6.7 Measurement Units

This option is provided for each meter channel to be configured with SI or US

units of measurement. Units for flow totalization (volumetric and mass) and flow

rate monitoring are configurable for each meter channel separately if the default

configuration is not applicable. Each meter channel may be configured to use

any of the standard units from liters/gallons to thousand cubic meters/barrels.

The flow rate period of each meter channel may be selected from flow rate per

second, per minute, per hour, or per day.

Advertising