12 prover data point events – ProSoft Technology MVI56-AFC User Manual

Page 148

Advertising
background image

Events

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 148 of 316

ProSoft Technology, Inc.

February 25, 2011

9.12 Prover Data Point Events

Note: Currently, this function is only available on the MVI56- AFC. For all other platforms continue
to use AFC Manager 2.05 or earlier.

Group

Sbgp

Item

DTyp

Rkv

Data point

0

0

Process input calibration ** not implemented

0

Flot

-

(Inlet) temperature

1

Flot

-

Outlet temperature

2

Flot

-

Switch bar temperature

3

Flot

-

(Inlet) pressure

4

Flot

-

Outlet pressure

0

1

Process input alarm ** not implemented

0

Flot

-

(Inlet) temperature range

1

Flot

-

Outlet temperature range

2

Flot

-

Switch bar temperature range

3

Flot

-

(Inlet) pressure range

4

Flot

-

Outlet pressure range

1

0

Prover classification

0

Diby

-

Prover type, master meter number

1

Diby

-

Measurement system, density selection

2

0

0

Bsht

-

Prover options

3

0

Prover run counts

0

Usht

-

Runs per prove, total

1

Usht

-

Runs per prove, selected

2

Usht

-

Max total runs before abort

3

Usht

-

Passes per run (short prover)

4

Usht

-

Min pulses per run * 1000

5

Usht

-

Max seconds per run

4

Prover input format codes

0

0

Usht

-

Pulse count for run/pass

1

0

Usht

-

Master meter pulse count

5

Prover reference conditions

0

0

Flot

*

Temperature

1

0

Flot

*

Pressure

6

Prover parameter value

0

0

Flot

-

Meter factor precision

1

0

Flot

-

Pulse interpolation ratio

2

0

Flot

-

Flow tube linear thermal expansion coefficient

3

0

Flot

-

Switch bar linear thermal expansion coefficient

4

0

Flot

-

Calibrated prover volume