Group

Sbgp

Item

DTyp

Rkv

Data point

0

0

0

Bsht

*

Stream options

1

Stream parameter value

0

0

Flot

*

Default relative density (gas) at reference

1

0

Flot

*

Viscosity

2

0

Flot

*

Isentropic exponent

3

0

Flot

*

Default Fpv

4

0

Flot

*

K/meter factor

5

0

Flot

*

Default energy content

6

0

Flot

*

Default reference density (liquid)

7

0

Flot

*

Default vapor pressure

8

0

Flot

*

Water density at API reference

9

0

Flot

*

Default Ctl

10

0

Flot

*

Default Cpl

11

0

Flot

*

Shrinkage factor

12

0

Flot

*

Precalculated alpha

2

0

Meter factor curve

0

Flot

*

Datum point 1, meter factor

1

Flot

*

Datum point 1, flow rate

2

Flot

*

Datum point 2, meter factor

3

Flot

*

Datum point 2, flow rate

4

Flot

*

Datum point 3, meter factor

5

Flot

*

Datum point 3, flow rate

6

Flot

*

Datum point 4, meter factor

7

Flot

*

Datum point 4, flow rate

8

Flot

*

Datum point 5, meter factor

9

Flot

*

Datum point 5, flow rate

3

0

Analysis mole fraction

** Because the item code extends into the subgroup
field, this can be the only subgroup of group 3 !

(Pending any future reformat of the Event Id Tag)

0

Usht

(5)

Component 1, scaled molar fraction

1

Usht

(5)

Component 2, scaled molar fraction

2

Usht

(5)

Component 3, scaled molar fraction

3

Usht

(5)

Component 4, scaled molar fraction

4

Usht

(5)

Component 5, scaled molar fraction

5

Usht

(5)

Component 6, scaled molar fraction

6

Usht

(5)

Component 7, scaled molar fraction

7

Usht

(5)

Component 8, scaled molar fraction

8

Usht

(5)

Component 9, scaled molar fraction

9

Usht

(5)

Component 10, scaled molar fraction