MVI56-AFC ♦ ControlLogix Platform

Modbus Communication

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 81 of 316

February 25, 2011

6.3.1 Example

The following table shows how the data types are implemented if a write function

is selected and the item count is configured with a value of 10 (decimal):

Data Type

Register
Type

Modbus
Function

Number of
Coils

Number of
Bytes

Number of
Registers

Number of words
(16-bits)
transferred

Bit

Coil

15

10

2

-

1

Word

Holding

16

-

20

10

10

Long

Holding

16

-

40

20

20

Long Remote

Holding

16

-

40

10

20

Note: The number of coils, bytes, and registers are part of the Modbus request (functions 15 and
16) according to the Modbus specification.


The following table shows how the data types are implemented if a read function
is selected and the item count is configured with a value of 10 (decimal):

Data Type

Register Type

Modbus Function

Number of Registers

Bit

Coil

1

10

Bit

Input

2

10

Word

Holding

3

10

Word

Input

4

10

Long

Holding

3

20

Long

Input

4

20

Long Remote

Holding

3

10

Long Remote

Input

4

10

Note: The number of registers is part of the Modbus request according to the Modbus
specification.


Refer to the ladder logic section for your module for more information about the

Modbus Master block.