13.2 BBRAM LEDs

The BBRAM (Battery Backed RAM) LEDs inform you about the condition of the

BBRAM hardware used for data storage. The following table lists the possible

situations that might occur during normal operation.

OK (Green)

ERR (Red) Description

ON

ON

The module is in a Cold Start condition that typically occurs when you
power up the module for the first time. After at least one meter is enabled

and the processor is in RUN mode the module starts operating.

ON

OFF

Normal Operation

Blinking

OFF

This condition is warning that a checksum flag was raised after a power
cycle. If this alarm issue occurs, refer to the AFC Manager (On-line

Monitor / Checksum Alarms) in order to determine the data section in

which the alarm issue has occurred. After verifying that the checksum
error has not affected the referred memory area you may clear the

checksum alarm using the same AFC Manager interface.
After the alarm is cleared the OK LED will be ON