Base prover volume (65036+)
Holds the base volume of the prover barrel as determined by the water-draw

method, in the units specified by Prover size units (register 65018.L). This

parameter is meaningful only for non-master meter provers.
The accepted standards mandate that the base volume of a bidirectional prover

be that registered by a round trip of the displacer.

Flow tube inside diameter (mm) (65038+)
This parameter is the measured inside diameter of the prover barrel at standard

(base) conditions and is meaningful only for non-master meter provers with the

option Prover is double-walled (register 65011 bit 5) clear.

Flow tube wall thickness (mm) (65040+)
This parameter is the measured thickness of the prover barrel wall, and is

meaningful only for non-master meter provers with the option Prover is double-
walled
(register 65011 bit 5) clear.

Flow tube modulus of elasticity (65042+)
This parameter is the prover barrel material modulus of elasticity, and is

meaningful only for non-master meter provers with the option Prover is double-
walled
(register 65011 bit 5) clear. The default value is that of carbon steel,

206.8e+6 kPa or 30.00e+6 psi.