Chapter 8: Hardware installation procedures 125

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Installing the Application Module

The following procedure for installing the Application Module is only one
of a series of procedures you should perform to install an Application
Module. The series is shown in Table 12 in Chapter 5, ÒHardware
installation overview.Ó Ensure that you have completed steps 1 through 5 in
Table 12 before you start the following procedure.

!

CAUTION

Risk of personal injury

Ensure that the circuit breaker of the Application Module
is in the off position.

Be careful when installing an Application Module
because it is heavy. This is usually a two-person job.

You can install an Application Module in either side of an AEM
(Application Equipment Module). Follow these steps:

1

Hold the Application Module by the bar on the top and align the
module with the guides at the top and bottom of the cage. Slowly
slide the unit into the AEM.

2

Tighten the four screws on the front of the module.

3

Position the subpanel, universal I/O panel, or generic I/O panel (as
supplied) at the rear of the module. Tighten or reinstall the screws
that secure the panel.

4

Attach the orange logic-return ground wire to the screw on the
terminal block at the bottom of the AEM.

5

Connect the yellow and gray cable from the power sense card to the
appropriate plug on the power monitor. If the module is on the right
side of the AEM (from the rear view), the cable connects to P1 on
the power monitor. If the module is on the left side, the cable
connects to P2.

Note: A connector housing surrounds the pins on the P1 and P2
connectors. Make sure you center the cable connector on the pins
within the housing.

Advertising