Option 11 esdi configuration – Meridian America Link/Customer Controlled Routing User Manual

Page 323

Advertising
background image

Chapter 12: Meridian 1 configuration for Meridian Link/CCR 305

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Configure ESDI or MSDL port (X11 Release 18 or later)

The IPE Module or the Application Module is connected to the Meridian 1
through a port on a QPC513 ESDI card (vintage G or later), NTAK02
SDI/DCH card (Option 11, IPE Module only), or NT6D80 MSDL card.

The port must have the Application Module Link (AML) identified
(VSID 0Ð15). Define the port and its characteristics by responding to the
following prompts in LD 17.

Option 11 ESDI configuration

Table 108
LD 17ÑConfigure ESDI port (Option 11)

Prompt

Response

Comment

REQ

CHG

Create or change information in the
database

TYPE

CFN

Configuration record data block

ADAN

NEW AML x

Add AML on port x (VASID 0Ð15)

CDNO

0Ð15

Serial Data Interface Card Number

PORT

0Ð3

Port number on SDI/DCH card

DES

LINK/CCR

AML port designation (such as
ÒMeridian LinkÓ)

BPS

19200

19,200 bps baud rate (19.2 kbps). The
AML (connection from SDI/DCH card
to the IPE Module) rate must match
the baud rate of link 0 on the IPE
Module.

CLOK

INT

Internal clock (this prompt only
appears for ESDI)

IADR

3

Individual address for the data-link
level-HDLC protocol

RADR

1

Remote address for the data-link level
HDLC protocol

ÐcontinuedÐ

Advertising