Chapter 9: Meridian Link/CCR interface cabling 197

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Figure 52
NT8D37 backplane cable designations (standard configuration)

Segment 3

Segment 2

Segment 1

Segment 0

S-1

L16 L15 L14 L13 L12

T-2

S-3

R-1

M-2

L-3

L-1

K-1

S-1

L11 L10 L9 L8

Shroud Row

1

2
3

L7 L6 L5 L4

E-1

F-1

F-3

G-2

S-2

T-3

T-1

R-2

R-3

M-3

M-1

L-2

K-2

K-3

E-2

E-3

F-2

G-1

G-3

L3 L2 L1 L0

A-1

B-1

B-3

C-2

A-2

A-3

B-2

C-3

C-1

Cabling for each segment can be expanded using one NT8D81AA
cable/filter assembly. Cabling for the entire backplane can be expanded
using four NT8D81AA cable/filter assemblies.

If you do not have additional NT8D81AA cable/filter assemblies available,
you can reroute the existing cables to accommodate the Meridian Link/CCR
IPE Module in specific PE slots. For more information on this, refer to the
NT8D37 backplane cable rerouting procedures (such as ÒNT8D37
backplane cable rerouting for segment 0Ñto accommodate the IPE Module
in PE slots 0Р3У) later in this section.