Chapter 9: Meridian Link/CCR interface cabling 179

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Figure 48
Option 11 main cabinet connector panel

0

1

2

3

4

5

6

7

8

9

¥

1

Ensure that the power for the IPE Module is turned off.

2

Connect NT1R03CA extension cables to the NT1R03AA and
NT1R03BA octopus cables using the 50-pin connectors. Using these
cables allows the front panel of the Option 11 to be closed without
interference from dangling cables.

3

Connect the NT1R03CA extension cable that is connected to the
NT1R03AA octopus cable to the appropriate connector cable as
shown in Tables 56 and 57. For example, if the IPE Module is
located in slots 2, 3, and 4, connect the extension cable to connector
J4.