448 Chapter 14: Software installation, upgrade, and update procedures

553-3202-210 Standard October 1998

Procedure 7: Reboot and go through setup

If you have just installed the operating system tape, ensure that you perform
the following procedure before you load the application tape.

Note: If you are upgrading Meridian Link to co-residency and your
Application Module needs an MVME332 ACC card, ensure that you
have installed the ACC card before starting this procedure (refer to
Procedure 29: Installing MVME332XT or MVME332XTS ACC card,
in Chapter 17, ÒHardware upgradeÓ).

1

Press the red RESET button on the MVME147 or MVME167 SBC
card or the IPE Module.

System start-up messages appear on the system console (see
Figures 202 and 203).

Figure 202
MVME147 Application Module start-up messages

Copyright Motorola Inc. 1989,1990, All Rights Reserved

VME147 Monitor/Debugger Release 2.42 - 08/01/91
CPU running at 25 MHz

FPC passed test
MMU passed test

COLD Start

Onboard RAM start = $00000000, stop = $007FFFFF
No offboard RAM detected

Figure 203
IPE Module or MVME167 Application Module start-up messages

Copyright Motorola Inc. 1988 - 1992, All Rights Reserved

MVME167 Debugger/Diagnostics Release Version 1.4 - 07/22/92
COLD Start

Local Memory Found =00800000 (&8388608)

MPU Clock Speed =25Mhz