Meridian America Link/Customer Controlled Routing User Manual

Page 200

Advertising
background image

182 Chapter 9: Meridian Link/CCR interface cabling

553-3202-210 Standard October 1998

5

Connect the ports of octopus cable NT1R03AA to external
equipment as described in Table 60 and shown in Figure 47. For
example, connect port 1 of the NT1R03AA octopus cable to the
console using a customer-supplied cable.

Table 60
Option 11 IPE Module external connections (NT1R03AA cable)

NT1R03AA

port

External equipment

External cable or reference

1

console

Customer-supplied cable. See
Table 62 for pinout.

3

conshare

See ÒSDI and ESDI/MSDL
cabling (Option 11 IPE Module
only).Ó

5

AML

See ÒSDI and ESDI/MSDL
cabling (Option 11 IPE Module
only).Ó

7

terminal/printer

NT1R03D

Ethernet

Ethernet LAN

See ÒInstalling Ethernet LAN
support.Ó

6

Connect the ports of cable NT1R03BA to external equipment using
extension cables, as described in Table 61 and shown in Figure 47.
For example, connect port 2 of the NT1R03BA cable to the external
modem using extension cable NT1R03HF.