Meridian America Link/Customer Controlled Routing User Manual

Page 509

Advertising
background image

Chapter 15: Link configuration 491

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Procedure 14: Changing Meridian Link (link 1) parameters (continued)

Table 142
X.25 and LAPB parametersÑLink 1 (continued)

Link parameter

Allowed values

(defaults in parentheses)

Description

Maximum Frame Length*

135

Baud rate

300 600 1200 2400 4800
9600 (19200) 38400
48000 56000 64000

Must be same as baud rate on the
Meridian 1 or host computer config-
uration; if modems are used, must
also match baud rate of the modem

Fail timer

0-(50)Ð9999

Timer value (in 1/10 second
increments) for monitoring the
signals that indicate link failure

RFS timer

0Р(150)Р9999

Timer value (in 1/10 second
increments) for monitoring CTS or
DTR signals after line opening

Internal address

(1), 3

1 for DCE; 3 for DTE

Remote address

1, (3)

3 for DCE; 1 for DTE. (This value
must be different from the value of
the internal address. The
combination of values for internal
address and remote address must
be the opposite of the values for
the host. That is, if the values for
the host are 3, 1, the values for the
link must be 1, 3.)

T1

0Р(20)Р9999

Frame recovery time (in 1/10
second increments); must be
identical to the time specified on
the host computer configuration

Maximum out frames (K)

1Ð(7)

LAPB window size; must be
identical to the size specified on the
host computer configuration

Note: Parameters marked with an asterisk (*) cannot be changed.

Ñ continued С

Advertising