Component failure rates – Meridian America Link/Customer Controlled Routing User Manual

Page 568

Advertising
background image

550 Chapter 20: Ordering

553-3202-210 Standard October 1998

Component failure rates

Failure rates for basic Application Module components in terms of the
number of expected failures in one million hours of operation are listed in
Table 152 and the rates for basic IPE Module components are listed in
Table 153.

Table 152
Application Module projected component failure rates

Part

number

Component

Failure rate

per million

hours

Mean

time

between

failures

NT7D18AA

Application Equipment
Module

1.43

699,500

NT7D62AA

Disk tape assembly

17.24

58,000

NT7D64AA

AM power supply, ac

13.89

72,000

NT7D64DC

AM power supply, dc

13.89

72,000

A0351919

MVME147 SBC card

11.98

83,500

A0600164

MVME167 SBC card

11.98

83,500

A0351167

MVME712AM transition
card with modem

11.98

83,500

A0352210

MVME333-2 XCC card

11.72

85,500

A0351166

MVME705B transition
card

16.67

60,000

A0376918

MVME332XTS ACC card

11.98

83,500

A0351356

TEAC MT-2ST/N50
cassette tape drive
- at 15 min per 8 hours

93.46
29.07

10,700
34,400

Advertising