206 Chapter 9: Meridian Link/CCR interface cabling

553-3202-210 Standard October 1998

Figure 54
NT8D11 backplane cable designations (segment 0 has been rerouted)

Segment 3

Segment 2

Segment 1

Segment 0

S-1

S-2

L16 L15 L14 L13 L12

T-2

T-3

S-3

T-1

R-1

R-2

R-3

M-2

L-3

L-1

K-1

M-3

M-1

L-2

K-2
K-3

S-1

L11 L10 L9 L8

Shroud Row

1

2
3

L7 L6 L5 L4 L3

E-1

E-2

E-3

F-1

F-2

F-3

G-1

G-2

G-3

L2 L1 L0

A-1

A-2

A-3

B-1

B-2

B-3

D-1

D-2

D-3

S-2

NT8D37 backplane cable rerouting for segment 1Ñto
accommodate the IPE Module in PE slots 4Ð7

1

Leave cable E as is in slot position L4.

2

Remove cable G from the backplane and connect cable ends G-1,
G-2, and G-3 to slot positions L7-1, L7-2, and L7-3.

3

Move the G connector on the I/O panel to position H. Now the cable
designation is changed from G to H.

!

CAUTION

Risk of hardware damage

With this cable rerouting, the IPE Module can only be
used in PE slots 4Ð7. Also, when the IPE Module is not
in PE slots 4Ð7, PE slot 6 should not be used at all.

Note: Reroute the cable only in the segment where the IPE Module is
going to be installed. Do not reroute the cable in other segments.