Chapter 9: Meridian Link/CCR interface cabling 203

Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

NT8D37 backplane cable rerouting for segment 0Ñto
accommodate the IPE Module in PE slots 0Ð3

With the cables located as shown in Table 67:

1

Leave cable A in slot position L0.

2

Remove cable C from the backplane and connect cable ends C-1,
C-2, and C-3 to slot position L3-1, L3-2, and L3-3.

3

Move the C connector on the I/O panel to position D. Now the cable
designation is changed from C to D.

!

CAUTION

Risk of hardware damage

With this cable rerouting, the IPE Module can be used
only in PE slots 0Ð3. Also, when the IPE Module is not
in PE slots 0Ð3, PE slot 2 should not be used at all.

Note: Reroute the cable only in the segment where the IPE Module is
going to be installed. Do not reroute the cable in other segments.