Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide

Chapter 19: Single Terminal Access

This chapter describes how to configure the Meridian 1 to support Single
Terminal Access (STA). STA is available with X11 release 19 and greater,
and provides integrated access to operation, administration, and
maintenance (OA&M) functions for the systems it monitors. STA allows a
single terminal to access the Meridian 1 and up to three other applications,
including Meridian Link/CCR. For more information, refer to the ÒSingle
Terminal AccessÓ chapter in the X11 System Management Applications
(NTP 553-3001-301).

Hardware and software requirements

To implement STA to support Meridian Link/CCR, the following hardware,
software, cabling, and connections are required:

¥

a VT220 terminal or compatible

¥

available ports on an MSDL card (NT6D80)

Ñ one for the STA terminal (must be port 0)

Ñ one for each STA-monitored system (Meridian Link/CCR)

Note: You can also use a port on the MSDL card for the AML
connection.

¥

one MSDL faceplate cable (NTND27) for the STA port

¥

one MSDL faceplate cable (NTND27) for each monitored system port

¥

one NT1R03 or NT7D58 cable for each monitored IPE system

¥

one NT7D61 cable for each monitored Application Module system

¥

one null modem adapter for each NT7D61, NT1R03, or NT7D58 cable