1 setting the voltage source for braking operation, 2 avoiding thermal overload of the brake resistor, Setting the voltage source for braking operation – Lenze 8400 BaseLine D User Manual

Page 103: Avoiding thermal overload of the brake resistor, Avoiding thermal overload of, The brake resistor, 5motor control (mctrl), Stop

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

103

5

Motor control (MCTRL)

5.7

Braking operation/braking energy management

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.7.1

Setting the voltage source for braking operation

The voltage threshold for braking operation is set via the mains voltage (

C173

) and the reduced bra-

ke chopper threshold (

C174

. When this "brake chopper threshold" is exceeded in the DC bus, the en-

ergy is dissipated in the DC bus via the brake resistor and the DC-bus voltage is reduced.

• The brake chopper threshold is preset as follows so that it is higher than the specified mains

(

C173

):

• This brake chopper threshold can be reduced by 0 ... 150 V via

C174

.

Example:

• A 400 V device has a maximum mains voltage of 420 V AC.

• Maximum stationary DC-bus voltage: 420 V AC * 1.414 = 594 V DC

C173

has been set with the selection "0" for 400 V AC mains.

• This means that

C174

can be set to a maximum of 131 V DC (725 V DC - 594 V DC).

5.7.2

Avoiding thermal overload of the brake resistor

• Parameterisation of an error response in

C574

and evaluation of the parameterised error mes-

sage within the application or within the machine control system.

• See chapter entitled "

Brake resistor monitoring (I2xt)

".

( 107)

• External interconnection using the thermal contact on the brake resistor (e.g. supply interrupti-

on via the mains contactor and activation of the mechanical brakes).

Mains voltage

Brake chopper threshold

C173

1-phase

3-phase

1-phase

3-phase

0

1ph 230V

3ph 400V

380V DC

725V DC

1

1ph 230V

3ph 440V

380V DC

35V DC

2

1ph 230V

3ph 480V

380V DC

775V DC

3

1ph 230V

3ph 500V

380V DC

790V DC

Stop!

The brake chopper threshold resulting from

C173

and

C174

must not exceed the statio-

nary DC-bus voltage!