3 terminals 11, 4 terminals 16, Terminals 11 – Lenze 8400 BaseLine D User Manual

Page 139: Terminals 16, 7drive application

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

139

7

Drive application

7.3

Setting parameters (short overview)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.3

Terminals 11

7.5.4

Terminals 16

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C011

)

DI1

LA_NCtrl.bSetSpeedCcw

DI2

LA_NCtrl.bSetDCBrake

DI3

LA_NCtrl.bMPotUp

NO, COM

LA_NCtrl.bDriveFail

DI4

LA_NCtrl.bMPotDown

DO1

LA_NCtrl.bDriveReady

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

Speed setpoint

Enable controller / reset error message

Direction of rotation CCw

Manual DC-injection braking (DCB)

increase speed

decrease speed

External supply 24 V DC

Motor potentiometer

DriveFail

DriveReady

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C011

)

DI1

LA_NCtrl.bJogSpeed1

DI2

LA_NCtrl.bJogSpeed2

DI3

LA_NCtrl. bRLQCw

NO, COM

LA_NCtrl.bDriveFail

DI4

LA_NCtrl. bRLQCcw

DO1

LA_NCtrl.bDriveReady

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Cw rotation - quick stop

CCw rotation - quick stop

External supply 24 V DC

DriveFail

DriveReady

Advertising