2 parameterise drive/application, Parameterise drive/application, 3commissioning – Lenze 8400 BaseLine D User Manual

Page 29

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

29

3

Commissioning

3.3

Commissioning with integrated keypad

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.3.2

Parameterise drive/application

The menu -2- of the integrated keypad contains all basic parameters to commission the drive/appli-

cation "actuating drive speed" quickly and easily for a terminal control. When you set these parame-

ters to suitable and sensible values, the controller can be operated properly.

More detailed information on the drive application:

Drive application

( 122)

Interface description

( 128)

Setting parameters (short overview)

( 133)

Pre-assignment of the drive application

( 134)

Terminal assignment of the control modes

( 137)

Parameter

Lenze setting

Info

Value Unit

C002/1

Load Lenze setting

0: Off / ready

Reset all parameters to the Lenze setting which are sa-

ved in the controller firmware.

C007

Select control mode

10: Terminals 0

Terminal assignment of the control modes ( 137)

C011

Reference speed

1500 rpm

All speed setpoint selections are provided in % and al-

ways refer to the reference speed set in

C011

.

The motor reference speed is given on the motor name-

plate.

C012

Acceleration time - main setpoint

2.0 s

The setpoint is led via a ramp function generator with li-

near characteristic. The ramp function generator con-

verts setpoint step-changes at the input into a ramp.

L_NSet_1 ( 230)

C013

Deceleration time - main setpoint

2.0 s

C015

V/f base frequency

50.0 Hz

Adapting the V/f base frequency ( 84)

C016

Vmin boost

0.0 %

Adapting the Vmin boost ( 85)

C022

Current limit (in motor mode)

47.00 A

Optimising the Imax controller ( 86)

C087

Rated motor speed

1460 rpm

Motor selection/Motor data ( 66)

C089

Rated motor frequency

50 Hz

C039/1

Fixed setpoint 1

40.0 %

A fixed setpoint for the setpoint generator can be acti-

vated instead of the main setpoint via the digital inputs

DI1 and DI2.

• The fixed setpoints are selected in [%] based on the

reference speed (

C011

).

L_NSet_1 ( 230)

C039/2

Fixed setpoint 2

60.0 %

C039/3

Fixed setpoint 3

80.0 %

C051

Actual speed value

- rpm

C054

Current motor current

- A

Highlighted in grey = display parameter

Advertising