1 l_mpot_1, L_mpot_1, L_mpot – Lenze 8400 BaseLine D User Manual

Page 226: Selec, Selection of the res, 10 function library

Advertising
background image

10

Function library

10.1

L_MPot_1

226

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.1

L_MPot_1

This FB replaces a hardware motor potentiometer and can be used as an alternative setpoint source

which is controlled via two inputs.

• The signal is output via a ramp function generator with linear ramps.
• The acceleration and deceleration times are set via parameters.
• Constant ramping even with speed limit values changed online.
• The motor potentiometer function can be switched on/off online via parameters or a process

signal.

Inputs

Identifier

Data type

Information/possible settings

bEnable

BOOL

Switch over motor potentiometer function

bEnable input and

C806

code are OR'd.

TRUE Motor potentiometer function is active, setpoint can be changed via

bUp and bDown.

• With switching to TRUE, the value applied to nIn_a is automati-

cally transferred to the motor potentiometer.

FALSE The value applied to nIn_a is output at nOut_a.

nln_a

INT

When bEnable = FALSE, the analog input signal nIn_ is switched to the nOut_a out-

put.

bUp

BOOL

Approaching of the upper speed limit value set in

C800

TRUE The nOut_a output signal runs to its upper limit value (nHighLimit).

• If the bDown input is simultaneously set to TRUE, the nOut_a out-

put signal is not changed.

bDown

BOOL

Approaching of the lower speed limit value set in

C801

TRUE The nOut_a output signal runs to its lower limit value (nLowLimit).

• If the bUp input is simultaneously set to TRUE, the nOut_a output

signal is not changed.

bInAct

BOOL

Deactivate motor potentiometer function

• This input has the highest priority.

• When the motor potentiometer is deactivated, the nOut_a output signal follows

the function set with code

C804

.

TRUE Motor potentiometer function is deactivated.

/B03RWB

E(QDEOH

Q2XWBD

Q,QBD

E8S

E,Q$FW

E'RZQ

,QLWLDOL]DWLRQIXQFWLRQ

&

/RZHUOLPLW

&

&

&

8SSHUOLPLW

$FFWLPH

& 'HFWLPH

'HDFWLYDWLRQIXQFWLRQ

&





&



&

&

&

&

&

Advertising