6.3

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Example
Task: Based on the preset control mode "Terminals 0", the digital input DI2 is used for activating the

quick stop instead of selecting the fixed setpoint 2/3. For this purpose, the digital input DI2 must

not be linked to the bJogSpeed2 input but to the bSetQuickstop input of the application.
Procedure:

1. Change the setting of the configuration parameter LA_NCtrl: bSetQuickstop (

C701/3

) which re-

presents the logical link of the bSetQuickstop application input: "0: Not connected"  "12:

DigIn_bIn2"

2. Change the setting of the configuration parameter LA_NCtrl: bJogSpeed2 (

C701/7

) which rep-

resents the logical link of the bJogSpeed2 application input: "12: DigIn_bIn2"  "0: Not connec-

ted"

[6-3]

Example: Changing the terminal assignment via configuration parameters

Tip!
The example shows, for each input of the application, the associated configuration para-

meter (

C700/x

or

C701/x

) is only allowed to contain one source that you enter.