5 keypad, Keypad, 7drive application – Lenze 8400 BaseLine D User Manual

Page 140

Advertising
background image

7

Drive application

7.3

Setting parameters (short overview)

140

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.5

Keypad

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

-

DI1

-

DI2

-

DI3

-

NO, COM

LA_NCtrl.bDriveFail

DI4

-

DO1

LA_NCtrl.bDriveReady

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

c003

c002

c001

_

`

-3-

-3-

ESC

_

`

_

`

C007

C007

0020

ESC

C728
C727

c003
c004
c005

Enable controller / reset error message

External supply 24 V DC

DriveFail

DriveReady

Speed setpoint

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Manual DC-injection braking (DCB)

Direction of rotation CCw

Quick stop

Menu

Code

Action