Function library

10.15

LS_ParFree_b

252

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.15

LS_ParFree_b

This system block outputs 16 parameterisable digital signals. The digital signals can be assigned to

other inputs via configuration parameters.

Outputs

Parameter

Related topics:

User-defined terminal assignment

( 115)

Identifier

Data type

Value/meaning

bPar1 ... bPar16

BOOL

Output of the signals levels (FALSE/TRUE) parameterised in

C470/1...16

Parameter

Possible settings

Info

C470/1...16

Selection of signal levels to be output

• Bit 0 ... 15 = bPar1 ... bPar16

0 "FALSE" signal is output
1 "TRUE" signal is output

E3DU