8.7.3

Short overview (A-Z)

The table below contains all error messages of the controller operating system in alphabetical order.

Tip!
If you click the cross-reference in the first column, "Error number", you get to the detailed

description of the respective error message in the subsequent "

Cause & possible remedies

"

chapter.

( 157)

Note!

For the sake of legibility, the

Logbook

and

C165

display the error number with the follo-

wing syntax:

[Error type].[Error subject area no.].[.].[Error ID]
In this documentation, "xx", a wildcard, stands for the error type since it is configurable

for many error messages.

Error number

Error message

Response

(Lenze setting)

can be set in

CAN Emergency

Error Code

xx.0125.00001

An01: AIN1_I < 4 mA

Fault

C598/1

0xF000

xx.0145.00001

dF01: Internal error 01

Fault

-

xx.0145.00002

dF02: Internal error 02

Fault

-

xx.0145.00003

dF03: Internal error 03

Fault

-

xx.0145.00004

dF04: Internal error 04

Fault

-

xx.0145.00005

dF05: Internal error 05

Fault

-

xx.0145.00006

dF06: Internal error 06

Fault

-

xx.0145.00007

dF07: Internal error 07

Fault

-

xx.0145.00008

dF08: Internal error 08

Fault

-

xx.0145.00009

dF09: Internal error 09

Fault

-

xx.0145.00010

dF10: Internal error 10

Fault

-

xx.0400.00105

dH69: Adjustment data error

Fault

-

0x5530

xx.0123.00057

ID1: Motor data identification error

WarningLocked

-

0xF000

xx.0123.00015

LU: DC bus undervoltage

Trouble

C600/1

0x3100

xx.0123.00016

OC1: Power section - short circuit

Fault

-

0x2000

xx.0123.00017

OC2: Power section - earth fault

Fault

-

0x2000

xx.0119.00050

OC5: Ixt overload

WarningLocked

C604

0x2000

xx.0123.00105

OC6: I2xt motor overload

WarningLocked

C606

0x2000

xx.0119.00052

OC9: Ixt overload - shutdown limit

Fault

-

0x2000

xx.0123.00065

OC12: I2xt brake resistance overload

Fault

-

0xF000

xx.0119.00001

OH: Heatsink overtemperature

Fault

-

0x4000

xx.0123.00014

OU: DC bus overvoltage

Trouble

-

0x3100

xx.0144.00001

PS01: No memory module

Warning

-

0x6300

xx.0144.00002

PS02: Par. set invalid

Fault

-

0x6300

xx.0144.00003

PS03: Par. set device invalid

Fault

-

0x6300

xx.0144.00004

PS04: Par. set device incompatible

Fault

-

0x6300

xx.0144.00031

PS31: Ident. error

Fault

-

0x6300

xx.0111.00002

Su02: One mains phase is missing

WarningLocked

C565

0x3000

xx.0980.00000

US01: User error 1

Fault

C581/1

0x6200

xx.0981.00000

US02: User error 2

Fault

C581/2

0x6200