Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

33

3

Commissioning

3.4

Commissioning with the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.4.2

Creating an »Engineer« project & going online

The following steps describe the standard procedure of creating a project using the Select

component from catalogue option. Here, you select the single components (controller, motor, etc.)

from selection lists.

1. Start the »Engineer«.
2. Create a new project by means of the Start-up wizard and the Select component from catalogue

option:

• In the Component dialog step, select the 8400 BaseLine D controller.
• Select the other components (motor/gearbox) to be added to the project in the Other

components dialog step.

3.

Go online.

• After a successful connection to the controller, the following status is displayed in the Status

line:

4.

Download parameter set.

• This command serves to overwrite the current parameter settings in the controller by para-

meter settings of the »Engineer« project.

You can find detailed information on the general use of the »Engineer« in the online help

which you can call with [F1].

• In the "Working with projects" chapter, all options of the start-up wizard are described

to create a new »Engineer« project.