Commissioning

3.3

Commissioning with integrated keypad

28

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.3

Commissioning with integrated keypad

Only a few parameters need to be adapted for the drive. Afterwards, the drive application can be im-

mediately controlled via the digital and analog inputs of the controller in the preset control mode

"Terminals 0".

Commissioning steps
In the following, commissioning of the controller using the integrated keypad is described step by

step. Please process the chapters consecutively and execute all steps carefully. This procedure will

help you to commission the controller quickly and as safe as possible:

Load Lenze setting

Parameterise drive/application

( 29)

Save parameter settings safe against mains failure

( 30)

Enable controller and select speed

( 31)

3.3.1

Load Lenze setting

In order to achieve a defined device configuration, it is advisable to make sure that the device is in

its original delivery state. For this purpose, the "Load Lenze setting" device command is available.

Information on how to use the integrated keypad can be found in the chapter entitled

"

Internal Keypad

".

( 18)

Step

Info

1.

Mains on

After the mains has been switched on and the keypad self test has been completed,

"00" is displayed

2.

After pressing the enter key:

Without password protection you have free access from here to all menus (and thus

all parameters).

3.

Select menu -2-.

• The menu -2- contains parameters for quick commissioning with terminal cont-

rol.

4.

Confirm selection.

5.

Confirm first code

C002

("device commands") of the menu -2-.

6.

Confirm subcode c001 ("load Lenze setting").

7.

Set value "01" (≡ "Start").

8.

Accept parameter setting to execute the "Load Lenze setting" device command.

Advertising