3 l_pctrl_1, L_pctrl_1, S controller – Lenze 8400 BaseLine D User Manual

Page 233: L_pctrl, 10 function library

Advertising
background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

233

10

Function library

10.3

L_PCTRL_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3

L_PCTRL_1

This FB is a PID controller and can be used for various control tasks (e.g. as dancer position controller,

tension controller, or pressure controller).
The FB is provides with the following functions:

• Adjustable control algorithm (P, PI, PID)
• Ramp function generator for preventing setpoint step-changes at the input
• Limitation of the controller output
• Factorisation of the output signal
• Vp adaptation
• Integral action component can be switched off

Inputs

Identifier

Data type

Information/possible settings

nAdapt_a

INT

Adaptation of gain Vp set in

C222

in percent

• Internal limitation to ± 199.9 %

• Changes can be done online.

• Display parameter:

C830/7

nNSet_a

INT

Speed setpoint

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.9 %

• Display parameter:

C830/10

nSet_a

INT

Sensor and process setpoint for operating modes 2, 4 and 5

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.9 %

• Display parameter:

C830/8

nAct_a

INT

Speed or actual sensor value (actual process value)

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.9 %

• Display parameter:

C830/6

E$FW(T6HW

E,2II

Q$FWBD

E(QDEOH,QIOXHQFH5DPS

Q,QIOXBD

Q2XWBD

Q16HWBD

Q6HWBD

Q$GDSWBD

&

&

&

&

&

&



&

&

7Q

&

9S

&

.G

_

_

_

_

&

__



&

Q3,'2XWBD

/B3&75/B

&

&

&

&

&

&

&

&